🇮🇪 Ireland · ARM4 · Work section

Walling & superstructure in a Ireland bill of quantities

In Ireland, the walling section of a Bill of Quantities (BoQ) is measured to ARM4 — Agreed Rules of Measurement (Ireland). It covers 6 principal groups of work — external walls below and above damp-proof course through to damp-proof course, wall ties and movement joints — and is headed in the bill as "WORK SECTION 3: WALLING & SUPERSTRUCTURE".

Walling & superstructure is one of the sections every Bill of Quantities (BoQ) in Ireland is built from. This page sets out what belongs in it, the unit each item is measured in under ARM4 — Agreed Rules of Measurement (Ireland), the local conventions that change the quantities here, and a worked example for a 150 m² house — plus the errors in this section that actually cost money on site.

Advertisement

What this section covers

  • External walls below and above damp-proof course
  • Internal loadbearing walls and partitions
  • Lintels over all openings
  • Ring beam or wall plate at eaves level
  • Reinforced concrete columns, beams and any suspended slab
  • Damp-proof course, wall ties and movement joints

How each item is measured

ItemUnitMeasurement rule
WallingMeasured on the mean face area, stating thickness and bond. Openings over about 0.5 m² are deducted.
Lintelsm or no.Measured as the clear opening width plus bearing each side, stating the section.
Ring beamm³ or mMeasured along the wall it caps, with reinforcement given separately.
Reinforcementkg or tonneMeasured to the bar bending schedule. Laps and spacers are deemed included in the rate.
FormworkMeasured on the surface of concrete requiring support — a separate and substantial item people forget entirely.
Damp-proof coursemMeasured on the wall length, stating the width.
Advertisement

Local conventions in Ireland

  • External walls here are conventionally 225 mm at about 110 units per m²; internal partitions 115 mm at 55 units per m².
  • Mortar is normally a 1:5 mix, and storey height is taken as 2.7 m.
  • Structural concrete is a 1:1.5:3 mix, with slabs reinforced at about 80 kg/m³ and columns at 180 kg/m³.

Worked example — 150 m² house in Ireland

Quantities for this section on a representative single-storey house, computed from Ireland construction conventions. Rates are deliberately not shown: they move constantly and are priced against your own drawings.

DescriptionQtyUnit
External walling units (bricks/blocks)
115 m² face × 110/m² × 1.05 wastage
13,254no.
Internal walling units
174 m² face × 55/m² × 1.05 wastage
10,042no.
Mortar cement
5 m³ mortar at 1:5
32bags (50 kg)
Mortar sand
1:5 mix, dry factor 1.33
5.6
Cement — general concrete
Footings and blinding, 12 m³
76bags (50 kg)
Cement — structural concrete
Slabs, 15 m³ at 1:1.5:3
121bags (50 kg)
River / pit sand
Combined concrete sand requirement
11.6
Coarse aggregate (stone)
Combined concrete stone requirement
23.2
Reinforcement steel
Slab 80 kg/m³, ring beam 110 kg/m³
1,420kg
Advertisement

What goes wrong in this section

  • Formwork is frequently omitted from owner-prepared bills and it can rival the cost of the concrete it shapes.
  • Deducting every small opening wastes measurement time for no commercial benefit; most standards set a threshold precisely so you do not.
  • Reinforcement quantities from rules of thumb are for budgeting only. A structural engineer's schedule governs — this is not a section to guess on.

Get every section measured, not just this one

Upload your dimensioned drawings and get a complete bill of quantities (boq) in the ARM4 format, priced in EUR (), with every rate source-cited.

Generate my Ireland BoQ

Walling & superstructure — frequently asked

What goes into the walling section of a bill of quantities in Ireland?

+

External walls below and above damp-proof course; Internal loadbearing walls and partitions; Lintels over all openings; Ring beam or wall plate at eaves level; and 2 further groups of work. Under ARM4 each is described, measured in its own unit, and priced separately so the total is auditable line by line.

What units is walling & superstructure measured in?

+

Walling in m², Lintels in m or no., Ring beam in m³ or m, Reinforcement in kg or tonne. Getting the unit right matters more than getting the quantity precisely right — a contractor can adjust a quantity, but cannot price an item measured in the wrong unit at all.

How is walling & superstructure different in Ireland from elsewhere?

+

External walls here are conventionally 225 mm at about 110 units per m²; internal partitions 115 mm at 55 units per m².

What is the most common costly mistake in this section?

+

Formwork is frequently omitted from owner-prepared bills and it can rival the cost of the concrete it shapes.

How do I get this section measured for my own project?

+

Upload your dimensioned drawings to Enormous Buildings. The bill is produced in the ARM4 format, grouped by section with walling & superstructure priced in EUR (€), and every unit rate carries a source so a Ireland quantity surveyor can check it.

The other sections of a Ireland bill

Keep exploring
Advertisement